AASHTO T48 (obs.)
ASTM D92
BS 4689 (obs.)
DIN 51376 (obs.)
EN 22592 (obs.)
FTM 791-1103
ISO 2592
IP 36
JIS K 2265
NF T60-118 (obs.)
Flash and Fire Point by Cleveland Open Cup Tester.
This test method describes the determination of the flash and fire point of petroleum products with flash points above 79°C (175°F) and below 400°C (752°F) except fuel oils.
Art. LT/CO-88000/M
Electric Cleveland
- Electrically heated by electronic regulator
- Mounted on a case painted with anti-acid epoxy products
- Calibrated brass cup
- Gas ignition device fitted with a pivot manually passing through the cup
- Pincers for thermometer