Abel Flash Point Tester: AB 5
Home > Products > Penetrometer, Fully Automatic model - PIVOT

Penetrometer, Fully Automatic model - PIVOT

Penetrometer, Fully Automatic model - PIVOT

EN 1426 | ASTM D5 | AASHTO T49 | JIS K 2207 | IP 49 | DIN 52210 | AFNOR T66-004 | ASTM D217


MAIN FEATURES
Details of the starting point determination in the digital water bath

Fully automatic operation. The entire test cycle (rapid approach, starting point determination, penetration and return to the initial position) is automatically performed by simply pressing the start button on the touch screen display
A rapid approach and automatic starting point determination to eliminate any operator inaccuracy during needle position
Penetration measurement via contactless displacement transducer, with 0.01 mm resolution
Real-time display of penetration/time curve
6" color touch streen display, easy to use thanks to the user friendly software
High precision vertical movement by stepper motor
Eight programmable reference positions for the holder assembly
Saves time and grants first class results

GENERAL DESCRIPTION

Most Standards make a degassing oven of the PAV-aged asphalt samples mandatory. The Vacuum Degassing Oven (VDO) is designed to remove air bubbles created during accelerated oxidative ageing of asphalt binder by the PAV. This final conditioning makes the aged binder suitable for further tests such as BBR, DSR, penetration, ductility, softening point and many more.

The apparatus consists of a stainless vacuum vessel with encased band heaters and integlral vacuum and temperature controls. A platinum RTD measures internal test temperature to +/- 0.1° C. Selectable test temperatures (from ambient to 200° C) are controlled to +/- 4.0° C.

The Vacuum Degassing Oven VDO can be used as part of your Superpave performance-based testing program.
Vacuum is provided by an integrated vacuum system and monitored by a pressure transducer and controlled to achieve 15 kPa absolute pressure.Temperature and vacuum are indicated both as set points and as actual values on the 6" digital color touch screen display. Temperature and vacuum calibration can be site executed. Data logs of both temperature and vacuum are saved on USB stick or transferred to PC at the end of the test.

The vacuum chamber can accept either eight 55x35 mm or four 70x45 mm (available as accessories) sample containers. The instrument is supplied complete with temperature traceable calibration certificate, 8 aluminium 55x35 mm sample containers,a double face sample holder and an operator's manual.

TECHNICAL SPECIFICATIONS

Working temperature range: ambient to 200° C
Temperature measurement: Platinum RTD with +/- 0.1° C resolution
Pressure measurement: pressure transducer wit +/- 1 kPa resolution
Power: 600 W
Dimensions, mm (l x w x h): 430 x 440 x 480
Weight (approx.): 30 kg